Clear-Com HX System Frames User Manual

Page 62

Advertising
background image


Key to Figure 20: Wiring an IMF-102 rear panel to a TEL-14 interface module

Connector

Instruction / description

A

DB-9M connector. Connects to the first telephone line, line A.

B

RJ-45 connector. Connects telephone line A to the matrix frame.

C

DB-9M connector. Connects to the second telephone line, line B.

D

RJ-45 connector. Connects telephone line B to the matrix frame.

Table 17: Key to Figure 20: Wiring an IMF-102 rear panel to a TEL-14 interface module

Note:

To allow use of a common RJ-11 terminated telephone line, Clear-Com provides two DB-9F
to RJ-11 adapters (Clear-Com part 770025).

For internal dip-switch settings and adjustments, see the TEL-14 manual.

Connecting a TEL-14 interface to the telephone line

Connecting the telephone line can be accomplished with one of two methods:

• Use the RJ-11 to DB-9F adapters supplied by Clear-Com with the TEL-14 interface

module.

• Directly wire each telephone line to a DB-9F connector using the pinouts as shown in

the following figure (which displays the wiring diagram of the RJ-11 to DB-9F
adapter
).

62

Eclipse HX Matrix Frame Installation Guide

Advertising
This manual is related to the following products: