8.6 E-QUE interface applications

The E-QUE interface may be used to connect:

• FreeSpeak/CellCom antennas and splitters to an Eclipse HX-Omega matrix.

• Provide E1 and T1 connections to other systems.

Tip:

For more information about E1 and T1 cable pinouts and cable connections, see:

4.9

E1/T1 Matrix to Matrix straight cable connections

.

4.10

E1 to FreeSpeak / CellCom antenna straight cable connection

.

8.6.1 FreeSpeak/CellCom application

The E-QUE interface cards can be configured for FreeSpeak/CellCom use in two modes,
depending on whether antennas or splitters are to be connected.

If the E-QUE interface card is configured:

• In antenna mode all eight E1/T1 ports can be used to connect up to eight antennas.

• To support splitters, only two ports are active (ports 1 and 5), allowing a maximum

of two splitters to be connected. Each splitter can support up to five antennas.

When the E-QUE interface cards are used in FreeSpeak/CellCom mode, they cannot be
connected to the antennas using either third party equipment or fiber. The DECT sync signal
required by the antennas will not be converted by third party equipment or fiber interface
cards.

Three connections schemes are illustrated below.