1 using the embedded configuration, Using the embedded configuration – Clear-Com HX System Frames User Manual

Page 59

Advertising
background image


Hardware serial number. For example, SERIAL 2251, in the case

where the HW serial number is 2251.

G

Full Reset button

When a full reset is performed, all cards in the matrix reset regardless of any
system preferences in the program software and non-volatile memory are
cleared.

To perform a full reset:

1. Press and hold the card’s lower RESET button (the Full reset button).

2. Simultaneously press and release the card’s upper RESET button.

3. Continue holding the card’s lower RESET button for two seconds.


The card then performs a full reset.

The same configuration that was active before the system was reset will be
active after reset.

When the cards and connected audio devices reset, they momentarily stop
their current activity and restart. During this process configuration information
is downloaded to the cards and audio devices from the CPU card’s non-
volatile RAM.

Note:

Under normal operating conditions it is not necessary to perform a full reset.
Technical personnel might perform a full reset if they believe that the CPU
card is operating incorrectly as a result of corruption of the microprocessor’s
internal data or instruction sequence.

Table 10: Key to Figure 18: CPU card lights and controls

5.5.1 Using the embedded configuration

In addition to the four EHX configurations that can be stored on the card, the CPU card also includes
an embedded configuration. The embedded configuration is designed for fast fault checking following
a system upgrade or field install (for example, checking hardware connections with user panels and
interface cards).

Note:

The embedded configuration may also be used as a back-up configuration, in the very rare event that
a system error renders the other configurations unusable.