Figure 35: Multiple matrices with DECT Sync Interconnect

Note:

All connections are made using CAT-5 cable and it is recommended that shielded cable is
used.

If an E-QUE interface is fitted in the matrix with antennae or splitters connected and active
inserting a second E-QUE interface to the left of the first interface (seen from the front) will
cause a temporary loss of audio to beltpacks using the original E-QUE interface (usually for
about 10 seconds). The beltpacks do not go offline and signalization is not lost.

8.7 E1 Trunk and Direct Modes

The E-QUE interface card can be used for both direct E1 to E1 port connections or to
provide trunk linking via a network between systems. The E1 connections can be made
between Eclipse HX systems or between Eclipse HX systems and compatible third-party
equipment. E1 mode provides 30 channels of G.711 or G.722 encoded audio available on
each of ports 1 and 5, giving 60 channels per card.

103