4 cpu card fail-safes, Cpu card fail-safes – Clear-Com HX System Frames User Manual

Page 54

Advertising
background image


If the network mask is extended to

255.255.255.0

the network ID becomes

172.16.2

so the second port could have an address of

172.16.3.1

and a mask of

255.255.255.0

giving a network ID of

172.16.3

for the second port.

If both Ethernet ports are set up with the same network ID this condition results in data loss
on one or both of the Ethernet ports.

Note:

Ethernet redundancy and the use of a default gateway is not supported. An IP address and
gateway combination on an Ethernet port means that all Tx traffic to any address is possible
on the port. Traffic that actually matches the other Ethernet port can therefore be sent out on
the wrong port.

5.4 CPU card fail-safes

The CPU card’s non-volatile memory stores all information about the current operating
configuration and the three additional configurations, allowing the system to restore itself
automatically after:

• A power failure.

• The replacement of a port card.

• The replacement of a panel.

An Eclipse HX-Omega system operates with either one or two CPU cards.

When a second card is installed, that card stores the four configurations in its RAM as a
backup to the main card. If the main card is removed or becomes non-operational for any
reason, the system will automatically switch to the second card as backup.