Sub-mode 05: Chose whether the Internal or External temperature sensor initiates commands

(Internal default)

a. Up arrow = External
b. Down arrow = Internal
c. Note that when using two INSTEON Wireless Thermostats with External temperature

sensor enabled, each INSTEON Wireless Thermostat will only display its local
reading and the INSTEON Thermostat’s reading. (INSTEON Thermostat will display
both INSTEON Wireless Thermostats’ readings.)

Sub-mode 06: Beep on button press (enable/disable, OFF default)

a. Up arrow = ON
b. Down arrow = OFF

Sub-mode 07: Button lock (enable/disable, OFF default)

a. Up arrow = ON
b. Down arrow = OFF

Sub-mode 08: Programming lock (enable/disable, OFF default)

a. Up arrow = ON
b. Down arrow = OFF

Sub-mode 09: Activation delay (default is 5 minutes)

a. Up arrow = Increase activation delay time
b. Down arrow = Decrease activation delay time
c. Range = 2 to 20 minutes


3) When finished, press and hold Program button to exit

Temperature and Humidity Calibration Modes

Note: Use a calibrated temperature or humidity source when adjusting INSTEON Wireless Thermostat.
1) Press and hold the Program button
2) Tap Time/Sensor to enter Temperature Calibration Mode
3) Tap Mode to step among internal temperature calibration (I), humidity calibration and external