INSTEON Wireless Thermostat Operation and Programming

Mode Button Operation

Off Mode:

No setpoints are shown

Up/Down arrows do not do anything

Heat Mode:

Only Heat setpoint is shown

Up/Down arrows change Heat setpoint

Heat setpoint range: 35°-95°F (2°C-36°C)

Cool Mode:

Only Cool setpoint is shown

Up/Down arrows change Cool setpoint

Cool setpoint range: 37°-97°F (4°C-38°C)

Auto Mode:

Both Cool and Heat setpoints are shown

Up/Down arrows increase or decrease
values by the same amount

Programmed Auto Mode:

The active program mode is indicated by
one of four annotations: Wake, Leave,
Return or Sleep

The annotation (Wake, Leave, Return or
Sleep) is not displayed in the other four
modes (Off, Heat, Cool or Auto)

Both Cool and Heat setpoints are shown

Up/Down arrows increase or decrease
values by the same amount

When the thermostat moves to the next
time period, the setpoints will be adjusted
accordingly

Note:

To adjust the gap between setpoints in Auto mode, press Mode to select Heat and set the
temperature you desire. Press Mode again to select Cool and set the temperature you desire.
Press Mode a third time to return to Auto; the settings will reflect your changes.