Important Safety Instructions

Read and Follow All Instructions All electrical work must be performed by a licensed electrician and conform
to all national, state, and local codes. Improper use or installation can badly harm the unit and its surround-
ings. When installing and using this electrical equipment, basic safety precautions should always be followed,
including the following:

DO NOT OPEN THE DISPLAY COVER OF THE BOX – NOT A SERVICABLE UNIT

• Disconnect all AC power before installation.

• WARNING – To reduce the risk of injury, do not permit children to use this product.

• The Control Box must be mounted vertically on a flat surface and at a minimum horizontal distance
of 5 ft (1.5m) (or more, if local codes so require) from the pool/spa.

• WARNING – Risk of electric shock. Connect only to a grounding type circuit protected by a ground
fault circuit-interrupter (GFCI) outlet. The installer should provide this GFCI requirement. The GFCI
should be rated for minimum 6 Amps and tested on a regular basis by pushing the test button. If
the GFCI fails to operate correctly, there is ground current flowing indicating the possibility

of electric shock. Do not use this unit. Disconnect unit and have a qualified professional

correct the problem before using.

• The Input circuit (LN1 & N/LN1) must be connected only after OVERCURRENT DEVICES, such as
fuse or circuit breaker to limit the amperage in the input wire to the maximum that is permitted by
the National Electrical Code.

• The Unit must be permanent connected, with copper wire, not less than 1.5 mm (14 Awg).

• The wiring of the unit must be performed according to the wiring instructions in the Installation

Manual or on the front box cover.

• A build-up of flammable fumes can result in a hazardous condition if the cell is allowed to operate
without flow. This device must be operated only with an approved in-line flow sensor.

• The flow sensor must be installed immediately before the POOL FROG® Mineral Hybrid Cycler
followed by the POOL FROG® Mineral Hybrid Cell.

• Ensure that equipment and materials used in or around the pool and spa are compatible with salt
based sanitation systems. Certain materials may be susceptible to salt and chlorine damage.

• ALWAYS ADD ACID TO WATER, NEVER WATER TO ACID.

• SAVE THESE INSTRUCTIONS.

This system is designed to work effectively with a variety of pool equipment

as long as the following basic procedures are followed.

IMPORTANT:

Pump run times of at least 6 hours per day at high speed are recommended for proper perfor-

mance. If running on low speed only (24 hours per day) or less than 6 hours per day on high

speed, bleed the air while the pump is running by unscrewing the cap knob on the Mineral

Hybrid Cycler until water appears, then screw the knob back on. Repeat this process each

time the cap is removed for any reason.