Reading the Control Panel

Salt Readouts

Normal salt level:

Normal salt level:
Salt level is normal
when the salt level
bar is in the “✔” area.

Note: The salt
readout takes up to
one minute to test
and display the salt
level.

High Salinity
Indication

The system safely
operates up to 5,500
ppm of salt. The
“High” salt indicators
illuminate to warn
against adding more
salt. If the High salt
indicators stay on, a
pool professional
should test the water
and dilute it as
necessary.

CAUTION: Check
with your local pool
professional prior to
draining or diluting
the pool.

Low Salinity
Indication

Scaling or coating of
the cell blades affects
the salinity reading.
Ensure the cell is
clean, then have the
pool water tested by
a pool professional
and adjust the salt
level to 3,000-4,500
ppm. See “Adding
the Salt” on page 6.

NOTE: The system safely operates in low levels of salt,
but its ability to produce chlorine decreases as the level
drops below 3000 ppm. A blinking bar in the “Output %”
area shows the amount of chlorine the system is trying
to produce, while the solid bars show the amont of chlo-
rine the system is actually producing.

Mode

There are 3 options that will appear when pressing the
Mode button

.

Push Once: pH Reducing NEED PUMP
• This can be ignored as it does not apply to this system.

Push Twice: Mineral Out Indicator
• To see how many days are left or to reset the time.

Push Three Times: Winter Setting
• To reset Mineral Out Indicator for next spring.

Standby Mode

When the main circulation pump turns off, the system
automatically goes into standby mode. This is a safety
action that prevents chlorine production without flow to
the cell.

Pool Cover Function/AUX Mode (for
use with automated retractable covers)

The unique pool cover function enables the chlorinator to
reduce the chlorine output while the pool is covered.
When the pool cover is closed, the chlorinator will auto-
matically reduce its chlorine output to 20% from the
maximum level and “AUX” will appear on the display.

Pressing

or

buttons while the system is in “AUX”

mode permanently sets new output values to the unit for
operation when the pool is covered. For example, the
default setting is 20%, but when the pool is covered you
may change the default setting to 40%. The setting will
return to 40% the next time the pool is covered. In order
to activate this function, make sure that the chlorinator
unit is getting a “closed” contact from the pool cover
control when the pool is covered.

High Salt

Very High Salt

Low Salt

Very Low Salt

Blinking

Icons

AUX