3. Program and Operation

3.11 Alarm Menu

/ ▼: move joystick up and down for selecting an item.

/ ▶: move joystick left and right for moving an item.

/ [Open] / [Near]: move joystick right to select or save settings or go to edit pages.

/ [Close] / [Far]: move joystick to cancel or to exit current menu (Back).

- Enter into {Main Menu}

- Using the joystick [▶], select Alarm Input type (NO / NC).

- Using the joystick [▶], select Alarm Output (On / Off)

- Alarm priority can be set using the joystick [▶],

Change an action / number {Off, Preset, Pattern, Scan, or Tour}.

- Set Alarm action time (Dwell Time): 3~60sec / On, default setting is ‘ON’.

-> Time Out (3~60sec): This is activated during a period of a selected dwell

time when an alarm is triggered.

-> Momentary (On): When an alarm is triggered, the dome camera will

maintain alarm activation continuously, until it is stopped manually

(96+preset or / and changing in alarm menu).

- It is possible to clear saved {Alarm No.xxx}, pressing [Wide] button at a position of

{No.xxx} individually.

- Press [Open] button or use joystick [▶] to save settings.

- Press [Close] button or use joystick to return to previous menu (Back).

* Notice:

In order to call an action (Preset, Pattern, Tour or Scan), you must save Preset, Pattern, Tour, or

Scan first. To pause alarming (about 10sec) temporarily, press [ESC] button or [96+preset].

* Notice:

The dome camera normally supports 4 Alarm Input (AL0~3). But AL3 can be used as Digital input

for External D/N, so, in this case, Only AL0~2 are available for Alarm inputs.

31

ALARM SETUP

NO. 001

: NOT USED

IN

:

OUT

:

PRIORITY :

ACTION

:

NUMBER

:

DTIME

:

SAVE : OPEN

BACK : CLOSE

- SET/CLEAR : (TELE/WIDE)