4. Troubleshooting Guide

If problems occur, check the installation of the dome with the instructions in this manual.

And refer to this manual for further information.

Problem

Solution

No video on the screen

- Verify that power is connected to all components in the system.

- Verify that the power switches are ON.

- Verify the status of cables or connection of cables

Poor video quality.

- Check the power supply voltage (normal 24VAC)

- Check the setting of camera.

- If the lens or the dome is dirty, clean up the dome windows with

a clean cloth.

Dome camera is not

working properly

(including wrong position of

dome camera)

- Re-cycle the power supply re-connecting the power code.

Or reset the dome camera using the Dome configuration menus.

[Main > System > Reboot]

- Check that the connection of power cable and assembling status

of dome camera.

- Initialize the dome camera. [Main > System > Initialize]

The communication between

controller and cameras

is not working properly.

(via 485 cable lines)

- Check that RS-485 communication cable is not connected

correctly. [Refer to 2.3 Connection Interface and Wire cables]

- Check ID/Protocol/Baud rate / Termination Setting.

[2.4 Setting Dome Camera]

- See the configure of [1.3 Termination Settings]

The surface of the

dome case is hot.

- Check the voltage level of the dome camera and the assembling

status of dome camera.

- Check that the dome camera is connected to the proper power.

The image on the

screen is flickers

- Does the camera face directly into the sun or fluorescent lamp?

If so, reposition the dome. Check for flicker-less setting of the

dome.

The PTZ is calibrated

without user control.

- The PTZ will be back on the original position as tuned after

12 hours automatically

- It will prevent an errors by unexpected shock.

32