8 operating conditions, 9 emc technical ratings, 10 emission specifications – Cleveland Motion Controls ULTRA ISC SERIES SLIM CELL TRANSDUCER REV AA User Manual

Page 12: 11 specifications, Perating, Onditions, Echnical, Atings, Mission specifications, Pecifications

Advertising
background image

U

LTRA

ISC

S

ERIES

S

LIM

C

ELL

T

RANSDUCER

MAN-70434-0

R

EV

AA

1.8 O

PERATING

C

ONDITIONS

Condition

Isolated Signal Conditioning Amplifier

Installation category

Category III

Pollution Pollution

Degree

2

Input supply

Earth (Ground) referenced

Protection Enclosure

mounted

1.9 EMC

T

ECHNICAL

R

ATINGS

Port

Phenomenon

Test Standard

Level

From Test Standard

Enclosure

ESD

EN 61000-4-2:

8KV AD, 1KV CD

EN 61326:1997

Enclosure

RF Field

EN 61000-4-3

10V/m,1 Khz AM

EN 61326:1997

Output Leads

Fast
Transient
Burst

EN 61000-4-4

1kV

EN 61326:1997

DC Supply
Leads

Fast
Transient
Burst

EN 61000-4-4

1kV

EN 61326:1997

DC Supply
Leads

Conducted
Immunity

EN 61000-4-6

3V/m

EN 61326:1997

Output Leads

Conducted
Immunity

EN 61000-4-6

3V/m

EN 61326:1997

1.10 E

MISSION SPECIFICATIONS

Port

Phenomenon

Test Standard

Level

Generic Standard

Enclosure Radiated

EN

61326:

1997

Class A

EN 61326:1997

The levels of performance indicated are achieved when the Isolated Signal Conditioning Amplifier is
installed by using the instructions and specifications outlined in this document.

1.11 S

PECIFICATIONS

Item:

Specification:

Transducer Weight

Slim Cell 1

Slim Cell 2

2.8 lbs.

1.3 kg

6.6 lb.

3.0 kg.

Weight + Bracket

Slim Cell 1

Slim Cell 2

5.5 lbs.

2.5 kg.

11.6 lb.

5.3 kg.

Material

Body and Side Plates – Stainless Steel 410

Bridge Resistance

135-147 Ohms @ 20

o

C

Gage Type

Semi-conductor strain gage, gage factor equals 95 (nominal)

Excitation Voltage

5.6 VDC maximum

(Excess voltage can cause permanent damage)

Nominal Output Signal at Rated

MWF

+/- 100 mV per Transducer (with 5 VDC excitation voltage)

P

AGE

12

OF

42