3.3 S

UMMING

B

Y

“S

ERIES

S

TACKING

The final interface approach to be discussed is to “stack” the two loadcell outputs by wiring the
analog outputs to be “series aiding”. Note that with each loadcell outputs at a maximum of 5VDC,
the sum would be 10 VDC. As should be obvious, loadcell signals greater than 5 VDC each will
likely take most PLC analog inputs over-range.

 

Figure 8 Stacking the Two Loadcell Outputs

Here is a simple example of software scaling and summing

Command Description

Sample (digitize) LCH and store

; Store digitized LCH.

Sample RCH and store

; Concurrent samples are best.

ADD LCH_OFSET to LCH parameter

; LCH_OFSET is the zero correction constant.

Multiply offset corrected LCH parameter by
LCHGAIN

; This scales the Left Channel for span

ADD RCH_OFSET to Digitized RCH parameter

; RCH_OFSET is the zero constant

Multiply offset corrected RCH param. by RCHGAIN

; This scales the Reft Channel for span.

Add resultant LCH and RCH parameters

; This is the composite tension feedback


Note that sometimes, over-sampling and filtering can be used to generate a robust tension
feedback parameter despite brief disturbances (either mechanical or electrical).