To ensure proper installation and operation of the system, keep the following points in mind:

 Do not apply shock loads to the Slim Cell bearing assembly when mounting or

dismounting rolls.

 Exercise care to avoid overstressing the transducer when handling partially mounted rolls.

Even relatively short rolls can afford an impressive mechanical advantage over the
sensitive transducer.

 Bolting the transducer to a non-flat surface can cause deformation of the transducer body

and degrade the quality of the tension signal.

Failure to follow these precautions can result in serious damage to the Slim Cell Transducers and
possibly void the warranty!

4.5 M

OUNTING THE

S

LIM

C

ELL

T

RANSDUCER TO THE MACHINE FRAME

The Slim Cell Transducer can be mounted directly to the machine frame or mounted using the optional
mounting bracket.

The mounting surfaces for the Slim Cell Transducer should be flat and parallel to each other. Remove any
loose paint, rust or scale from the machine frame before mounting.

When Mounting the Slim Cell Transducer Directly to
the Machine Frame:

When Mounting the Bracket to the Machine Frame:

 The Slim Cell can be mounted on either

the inside or outside of the machine
frame. Refer to Figure 10 to help
determine the arrangement that best suits
your application.

 Before drilling and tapping the mounting

holes in the machine frame, refer to
section 4.6 to ensure proper alignment of
the Slim Cell.

 Mount the Slim Cell Transducer into

place with three bolts. For properly
positioned bolt hole centers and sizes,
refer to the dimensions listed for letters B
and M in Error! Reference source not
found.
. The bolt hole centers are evenly
spaced on a circle and 120 degrees from
each other.

 The transducers can be mounted on either

side of the bracket. Refer to Figure 10 to
help determine the arrangement that best
suits your application.

 Drill and tap two mounting holes in the

machine frame for each bracket. Refer to
dimension X, O and P in Table D for
correct dimensions for the bolt holes.