Cleveland Motion Controls Quantum Tension Controller REV A User Manual

Page 26

Advertising
background image

www.cmccontrols.com

26

Menu FUNCTION

4.5 NO-STOP function

Principle

This function is used to manage two independent outputs (one which is the calculation result
output and the second one which is fixed - hold value). This is usually very useful to manage
the automatic splice turrets systems.

How does it work

Click in the "No-Stop" special function box to enable the function.

The ouptut currently not affected by the calculation is automatically delivering the Hold or the
E-stop value, depending on the status chosen for logical inputs A and B.

Process

See the following table:

A B

AO1

AO2

0 0

Regulation

Hold

0 1

Regulation

E-Stop

1 0

Hold

Regulation

1 1

E-Stop

Regulation

0 means Open / 1 means Closed

NOTE:

When using this "No-Stop" function, the "Demagnetization" function is not available.
The Operator control panel (front face keyboard functions) remains the priority control.
That means that "Hold" or "Freewheel" modes are sent simultaneously on both AO1 and AO2.

Advertising