5typical application examples, Open loop, Initial set of parameters – Cleveland Motion Controls Quantum Tension Controller REV A User Manual

Page 5

Advertising
background image

5

TYPICAL APPLICATION EXAMPLES

WIRING UNWIND WITH EMAG BRAKE AND ULTRASONIC SENSOR

OPEN LOOP

Com

+24

C1

C2

V+

A

B

V+

Init

Reg

Com

DM

+24

+24 V

AC / DC

EMAG

Brake

Ultrasonic

Sensor

+

-

S

Blue

Bleu

Y

ellow

Jaune

Brown

Brun

Jumper

NR7

Initial set of parameters

File : Diameter_measurement.prm

DISPLAY

Line 1

Set Point

Line 2

Diameter

FUNCTIONS

Time Delay Start
Time Delay Stop
Hold

INPUTS

Set Point

50

Diameter Filtering

1000

Tachymeter Filtering

OUTPUTS

Upper Limit

0

Bottom Limit

10

Power Gain

100

REGULATION Max Effort

100

P
I
D
Measurement Filtering
Open Loop Gain

100

Closed Loop Gain
Speed Gain
Coeff Speed
Overspeed

Note : all Com / 0V are linked to the ground

Troubleshooting

Check:

All wiring, in particular ensure cable

shields are properly connected

Ensure the parameter settings are in

full accordance with the related
applications tables

Stability:

When necessary adjust the parameters
(*) to improve the system stability

Note:

Variable PID (coefficients are

proportional to the diameter) is also
available when system stability cannot
be obtained (diameter measurement
must be available).

Detailed features about the Variable

PID are fully available in the Help file
included to the PC software

CAUTION:

Ensure the required “Process” (link

to the machine automation) is
active before starting the system
(logic input B)