System schemetic, Wiring camera control port and sensor / alarm port, 9 / 16 channel dvr user guide – CNB SDN2712CD User Manual

Page 9

Advertising
background image

9 / 16 Channel DVR User Guide


9

SYSTEM SCHEMETIC

Wiring Camera Control port and Sensor / Alarm Port

(+)

(-)

(+)

(-)

Alarm Out

1

2

3

4

A

B

A

B

A

B

A

B

+12VDC

RS-422/485

TX+ TX- RX+ RX-

1 2 3 4

RS422 R485

1 TX+
2 TX-
3 RX+ DATA+

4 RX- DATA-

Sensor In(1~16)

1

2

3

4

Dried Contact

Sensor

Adapter

G

5

6

7

8

G

9

10

11

12

G

13

14

15

16

G

SENSOR INPUT :Connect two signal lines of sensor (infrared rays sensor, heat perception sensor,

magnetic sensor) to the desired sensor number.

(You can set the type-NC or NO- of sensor at “Setup” mode).

ALARM OUTPUT : Use this at 30V/300mA or less operating voltage and current.

When controlling lamp and AC operated equipment, control it using separate outside relay.

During normal operation the control output contact is maintained at “Open” status, and during

control output the output contact is changed to “Close(short)” status.

SENSOR inputs need dried contact only. Do not input any electric signal.

4

E

N
G

L

I

S

H

Advertising