Total currant draw from the +12V_Aux (J5-Pin 1) should not
exceed 150 Milliamps.

Figure 10 Feedback Frequency

Quadrature Single-Ended Sensor (Bidirectional)

Feedback Frequency

(J5 pins 1, 7, 8, 9, 10, 11)
Frequency Input 2

The FEEDBACK FREQUENCY detects the controlled motor speed. The wiring for FEEDBACK
FREQUENCY is determined by the sensor. Figures 9 through 12 illustrate the wiring for the various
sensors. For signal level and performance specifications refer to

CX-1010 Technical Reference Manual,

Appendices: Appendix A.

Figure 9 Feedback Frequency

Quadrature Differential Sensor (Bidirectional)

*

Total currant draw from the +12V_Aux (J5-Pin 1) should not
exceed 150 Milliamps.

+12V Pwr

A

A

B

B

Common

1

7

8

9

10

11

J5

*

+12V_Aux

FI_2A

FI_2A

FI_2B

FI_2B

COM

+12V Pwr

A

B

Common

1

7

8

9

10

11

J5

*

+12V_Aux

FI_2A

FI_2A

FI_2B

FI_2B

COM