Block select c, Setpoint direction – CONTREX CX-1010 User Manual

Page 20

Advertising
background image

Page 18

Block Select C

(J7 pins 3,4)
Digital Input 10

Use BLOCK SELECT C in conjunction with BLOCK
SELECT A and BLOCK SELECT B inputs to select one
of the eight Parameter Blocks. Refer to the chart below.

Setpoint Direction

(J7 pins 3,5)
Digital Input 11

Use SETPOINT DIRECTION in conjunction with a
positive or a negative setpoint parameter value to select
either a forward or reverse command direction. Refer to
the chart below.

Figure 22 Block Select C

BLOCK
SELECT C

3

4

J7

COM

DI_10

Figure 23 Setpoint Direction

POSITIVE

3

5

J7

NEGATIVE

COM

DI_11

Block

Select A

Open

PARAMETER

BLOCKS:

Block

Select B

Block

Select C

0

1

2

3

4

5

6

7

Closed

Open

Open

Open

Closed

Closed

Closed

Open

Open

Open

Open

Open

Closed

Closed

Closed

Closed

Closed

Closed

Closed

Closed

Open

Open

Open

Advertising