Ac power, Lead frequency – CONTREX ML-TRIM User Manual

Page 22

Advertising
background image

2 - 8

AC Power

(J3 pins 1, 2, 3)

The ML–Trim model #3200-1931
operates on 115 VAC + 15%, 0.1
Amp., 50/60 Hz. The ML–Trim model
#3200-1932 operates on 230 VAC
+ 15%, 0.1 Amp., 50/60 Hz.

* Fuse L1 for 115VAC applica-
tions. Fuse L1 and L2 for
230VAC applications. Use
1 Amp 250V normal blow
fuses.

Lead Frequency

(J5 pins 3, 5)

The Lead Frequency is a pulse train
input that the ML–Trim uses to
determine the speed of the lead
motor. For signal level specifications,
refer to

References: Appendix A

,

ML–Trim Specifications,

page A-1

Figure 2-5 Input Power

Figure 2-6 Lead Frequency

L1

Neutral or L2

GND/PE

1

2

3

J3

*

*

Signal

Common

3

5

J5

Advertising