Inverse follower mode, Inverse follower mode -24 – CONTREX ML-TRIM User Manual

Page 58

Advertising
background image

3 - 24

Inverse Follower Mode

The Inverse Follower Mode is a variation of the Follower Mode. The Inverse Follower
Mode has an inverted setpoint. If you increase the value of the setpoint (CP-03 or
CP-04), then the ratio of Follower speed to Lead speed will decrease.

With the Inverse Scaling (CP-62) set to “2”, enter values in the Follower Setpoints
(CP-03 and CP-04) that represent the E.U. at which you want the system to operate.
The higher the setpoint value; the lower the Follower to Lead ratio speed.

The ML–Trim comes factory pre-loaded with the default Control Parameters for the
standard Follower Mode. These default settings are not suitable for Inverse
applications and require modification. The factory default Control Parameters for the
standard Follower Mode are found in Table 3-16. To modify these default parameters,
refer to Table 3-17. If you are uncertain how to enter a Control Parameter, review the

Operations: Keypad

section, page 3-3.

Table 3-16 Default Inverse Follower Control Parameters

CP

Parameter Name

Parameter Value

CP-62

Inverse Scaling

1 (Standard Scaling)

CP-21

Follower E.U.

1.000

Table 3-17 Entering Inverse Follower Control Parameters

CP

Parameter Name

Parameter Value

CP-62

Inverse Scaling

Enter “2” for Inverse Scaling.

CP-21

Follower E.U.

Enter the minimum Engineering
Units if the system were to operate
at the Max RPM Lead (CP-33) and the
Max RPM Feedback (CP-34).

Advertising