Motor drive set up, Motor drive set up -18 – CONTREX ML-TRIM User Manual

Page 32

Advertising
background image

2 - 18

MOTOR DRIVE SET UP

1) Put the ML–Trim in “R–Stop” by opening the R–Stop input (J5 pins 9, 11).

Refer to

Installation/Setup: Wiring, Inputs, R–Stop,

page 2-10.

2) Set the drive's Acceleration and Deceleration potentiometers to their fastest

rates (minimum ramp time). The goal is to make the drive as responsive as
possible, which allows the ML–Trim to control the speed changes.

3) If the drive has a Maximum Speed (Span) Potentiometer, set it to the highest

setting at which the motor drive is capable of running. The maximum speed
at which you want the system to operate will be controlled by the ML–Trim.

4) If the drive has a Zero Speed Potentiometer, adjust it to eliminate any motor

creep.

5) If the drive has an IR Compensation Potentiometer, set it at minimum.

6) Each motor drive has settings that are unique to its particular model. Adjust

any remaining drive settings according to the manufacturer's
recommendations.

Advertising