2 receiver banks – CTI Products MCN RCD System Overview User Manual

Page 20

Advertising
background image

MCN System Manual

System Operation

CTI Products, Inc.

68-10833-120

16

CA-80049-100

+V

+V

MOMENTARY

+V

+V

LATCHING

CONSOLE ELECTRONICS

IIB J1

VOTE

FAIL

RX

DISABLE

Figure 4 - Console Electronics Interface

When the DISABLE button on the console is pressed, the DISABLE LED on the
console will immediately turn on and stay on after the DISABLE button is
released since it is a latching button. The IIB will send the DISABLE information
to the Comparator I/O Module so that the comparator will disable the receiver. If
the DISABLE does not occur (the MCN network is not connected or the receiver
is Force Voted so the comparator ignores the DISABLE), the operator at the
console may not know it because the console’s DISABLE LED is on.

The hardware reference manual of the CIB and IIB indicate which I/O lines are bi-
directional and when this type of a problem will occur.

6.2 Receiver

Banks

The CIB parallel Comparator Interface Module controls and monitors 8 receivers.
The AIB supports up to 13 receivers when configured for an ASTRO-TAC™
Comparator or up to 64 receivers when configured for an ASTRO-TAC™ 3000
Comparator.