CTI Products MCN RCD System Overview User Manual
Page 31
MCN System Manual
Hardware Installation
CTI Products, Inc.
68-10833-120
27
DIGITAC Mounting Instructions
Step
Operation
1
Remove all cables from the CIB.
2
Attach the small mounting plate, using the 6-32 X 1/4 screws provided,
to the bottom of the CIB module.
3
Attach CIB/plate assembly to the mounting bracket using the 8-32 X 1/4
screws provided.
4
Remove the 4 screws from the back of the DIGITAC, as indicated in
Figure 10.
5
Connect the provided cable to the back of the CIB and route the cable
underneath the DIGITAC mounting bracket.
6
Position the DIGITAC mounting bracket on the back of the DIGITAC
so that the bracket’s mounting holes line up with the DIGITAC’s screw
holes.
7
Re-install the 4 screws (from step 4) in the back of the DIGITAC.
8
Attach other end of the cable to P805 of the DIGITAC.
9
Connect the CIB power and network cables.
With the CIB mounting bracket installed on the back of the DIGITAC, an