Figure 5 - mcn bank configuration example – CTI Products MCN RCD System Overview User Manual

Page 21

Advertising
background image

MCN System Manual

System Operation

CTI Products, Inc.

68-10833-120

17

For Comparator I/O Modules, such as the AIB module, that support more than 8
receivers, the receivers are grouped into banks of 8 receivers. Some User
Interface Modules, such as HIBs operating with the MCN Remote Comparator
Display software support only bank 0. Other User Interface Modules, such as the
IIB, can be configured to control any one of the 8 banks.

Below is a list of the MCN banks and the receivers contained in those banks.

Bank

Receiver Numbers

0

1 through 8

1

9 through 16

2

17 through 24

3

25 through 32

4

33 through 40

5

41 through 48

6

49 through 56

7

57 through 64

Table 2 - MCN Receiver Banks

In the example shown in Figure 5, the ASTRO-TAC™ Comparator supports 13
receivers. The AIB divides the receivers into two banks (receiver banks 0 and 1)
for its communications with the User Interface Modules (the IIB modules). Two
IIBs are installed in the example system to support these 13 receivers. When the
IIBs were installed, each had to be configured (through front panel option
switches) for the bank of receivers that each will be monitoring. The first IIB is
configured to monitor receivers 1 through 8 (bank 0). The second IIB is
configured to monitor receivers 9 through 13 (bank 1). With this configuration,
the console can monitor and control receivers 1 through 13.

CA-80044-100

OUT

P/S

IN

IN

OUT

T

T

COMPARATOR

CONSOLE

ELECTRONICS

IN

OUT

AIB

ASTRO-TAC

13 RECEIVERS

IIB

BANK 0

IIB

BANK 1

CONSOLE

Figure 5 - MCN Bank Configuration Example