DC Power Connection
DC power must be attached to the HIB-IP module via the DC IN
connector. A wall plug-in style power supply designed for the HIB-IP
module is an available option.
C) Program IP Parameters:
The IP parameters are downloaded from the PC to the HIB-IP unit using a serial cable.
1. Be sure all the HIB-IP and Authorized PC parameters have been entered into the PC configuration files
using MCN Config series software as described in Section: 2. IP Address Configuration.
2. IP traffic can interrupt programming or viewing the data on a HIB-IP unit.
Remove IP traffic by disconnecting the Ethernet cable from the 10Base-T port on the rear of the HIB-
IP unit.
3. Connect a Null Modem cable (CTI # 89-11314) between the PC and the Async
Serial Programming connector on the HIB-IP.
Use of different cables may result in inconsistent or improper programming and
viewing of HIB-IP data.
See Appendix D. HIB-IP Programming Cable Pinout 89-11314 on page 25 for the proper cable pinout.
4. Load the IP parameters to the HIB-IP using the MCNConfig program:
Go to the Network Interfaces window and select the proper HIB-IP unit.
Right-click on the HIB-IP unit and select "Load HIB" from the pop-up window.