Testing, Http, Tatus – CTI Products HIB-IP IP Interface User Manual

Page 17: Esting

Advertising
background image

CTI Products, Inc.

HIB-IP & HIB-IP 8000 Hardware Reference Manual

Appendix A. Factory Default Settings

17

4.

T

ESTING

HTTP

S

TATUS

P

AGE

The HIB-IP and HIB-IP 8000 units have an HTTP page that shows the status of the unit, including the IP
parameters programmed into it and its On-Line / Off-Line status. This is useful for system troubleshooting. .

On the HIB-IP 8000 units, this feature is turned off at the factory by default.

Connect your PC to the HIB-IP via a LAN and enter the IP address of the HIB-IP in the address window:
Option Switch 2 must be Up for this page to be active.

The HTTP Status Page lists the current configuration for the HIB-IP unit.

Obviously, if the HIB-IP unit's own IP parameters are set wrong, you won't be able to see the Status Page.

Note: Some networks (including Motorola Solutions, Inc. Radio Network Infrastructure - RNI) have routers
and/or firewalls that restrict HTTP traffic between certain network segments or subnets. If you have such a
system, you may not be able to open the HTTP page from a different IP segment or subnet, even if you have
the HTTP page enabled on the HIB-IP unit.















Data entered from MCN Config program
(except for MAC Address)



On-Line Status indicator:

False:

No PC Connected

True

PC running MCN Software is connected

to HIB-IP unit.