HIB-IP & HIB-IP 8000 Hardware Reference Manual

1. Introduction

7

F

RONT

P

ANEL












1

2

3

4

5

9

8

7

6

ERR

ACT

PWR

RESET

WINK

ETH RX

ETH TX

CSVC

RSVC

NETWORK

OUT

IN

ASYNC

NETWORK

NCB

NETWORK COMBINER

Figure 2 HIB-IP Front Pane

MCN Network Note 1

Unlike most other MCN modules, the HIB-IP does not inject power into the Network Out connector. It also
does not use any DC power from the Network In connector. All 8 pins on the Network In & Out connectors are
paralleled, so that any power from other modules will be passed through.

MCN Network Note 2

Although the MCN Network connectors are RJ-45s, THEY ARE NOT ETHERNET CONNECTORS. Because
the MCN network connectors on the front of the units may have DC power on them from other MCN devices,
DO NOT CONNECT THE NETWORK IN OR OUT CONNECTORS TO ETHERNET PORTS. THIS CAN
DAMAGE THE ETHERNET DEVICE. The Ethernet cable should be connected to the 10BASE-T connector on
the rear of the HIB-IP unit.

Front Panel Indicators – Additional Information

ETH RX LED (Yellow) – Indicates when a packet has been detected on the Ethernet port. NOTE: Flashing of
this LED does NOT necessarily mean that a packet addressed to this HIB-IP module has been received, just that
a packet has been detected on the Ethernet network.

ERR LED (Red) – Indicates a possible error condition. See Table E2 in Appendix E for a list of Error Code
definitions.

ETH TX LED Indicates when a packet has been

transmitted on the Ethernet port

WINK LED

Normally not used.
May be winked during Custom
Configuration to identify a unit.

ETH RX LED Indicates when a packet has been

detected on the Ethernet port

MCN NETWORK Connections

RJ-45 Normal Network connection.
Screw Terminals not normally used.

*** See MCN Network Notes 1 & 2***

Async Serial Programming Connector

Used with PC running MCNConfig
to access IP address parameters

RESET Button

Buttons for use with Custom
Configuration
Press only when requested.

CSVC Button Identifies Control Processor
RSVC Button Not used

PWR LED Indicates correct input power
ERR LED

Indicates an error condition
(see below and Appendix D)

ACT LED

Indicates that a PC has
connected to the HIB-IP.