EMG-1000 & EMG-1500 Gel Coat Gun


Disassembly

WARNING: Always remove fluid pressures before working on the unit.

WARNING: Be careful not to bend the catalyst and resin needles.

Initial Disassembly . . .

1.

Remove Catalyst, Resin and Air pressure from system before disassembly.


2.

Remove Catalyst, Resin and Air lines from the Gun Block Assembly.

3.

Remove Screw (00145) from Trigger Stud (54630-1).

4.

Remove Trigger Stud (54630-1) from Gun Handle and Trigger (MAX-2040).


5.

Remove Trigger (MAX-2040) from gun assembly.


6.

To remove the Gun Block Assembly (EMG-1001-01) from Gun Handle remove
Cap Screw (F-CS-04C-12) located at the back center, just above the Gun Block
Assembly.

You now have two components, the Gun Block Assembly and Gun Handle Assembly.