Warning, Inspection and maintenance of unit – Magnum Venus Plastech Gel Coat Gun EMG-1500 User Manual

Page 9

Advertising
background image

WARNING

Static Spark

Can Cause explosion resulting severe injury
or death.

Ground pump and pumping
system

Injection Hazard

Any material injected into flesh can cause
severe injury or death.

Keep body parts away from
outlet device. If an injection
occurs, immediately obtain
medical attention.

Hazardous
pressure

Sudden pressure release can cause severe
injury or death.

Pumping system can remain
pressurized when pump is not
operating.

Excessive inlet
pressure

Can cause severe injury or death

Do not exceed the maximum inlet
pressure as stated on the model
plate.

INSPECTION AND MAINTENANCE OF UNIT

1) Check solvent cup to be sure it is 1/3 full.
2) Check catalyst and material levels.
3) Inspect material spray tip and o-ring. Replace if necessary.
4) Inspect catalyst tip assembly and o-rings. Replace if necessary.
5) Inspect tip pin o-rings on front of gun head and replace if nicked or worn.
6) Assemble catalyst tip and material tip onto gun.
7) Lubricate threads on retaining ring and assembly onto gun.
8) Inspect hose assemblies and connections for leaks and wear and tear. Replace if

necessary. Do not wait until hose is so worn that it may burst.

9) Check roving quantity (if applicable).
10) Inspect and replace if necessary:

a) Chopper Blades
b) Anvil Sleeve
c) Cutter Head Bearing
d) Idler Bearing

11) Inspect and adjust if necessary:

a) Cutter head to Anvil Sleeve tension
b) Idler Bearing to Anvil Sleeve tension
c) Check Chopper position for most efficient disbursement of chop into spray

pattern.

12) Oil Cutter assembly Air Motor with Magnum Air Motor Oil as necessary (normally 2

3 drops daily, depending on usage).