Gun head assembly – Magnum Venus Plastech Gel Coat Gun EMG-1500 User Manual

Page 18

Advertising
background image

Gun Head Assembly

1.

Install a new O-ring (O-S-012) onto Check Valve Assembly and thread it into the
catalyst fitting position.


2.

Place a new O-Ring (O-S-012) on Resin Fitting (55500-1) and install into the gun
block.

3.

Install new O-Ring (O-S-012) into Catalyst Needle Seat area of the Gun Head
(EMG-1001-01).


4.

Install the new Catalyst Needle Seat (CPR-2012-02) onto the end of the Catalyst
Needle Housing (CPR-2003-02).

5.

Install new O-Ring (O-S-012) on Catalyst Needle Housing (CPR-2003-02) and
thread into Gun Block (EMG-1001-01).

6.

Thread Jam Nut (53800-1) then Needle Guide (53900-1) onto catalyst needle
end.

7.

Install new O-ring (O-S-006) onto the Catalyst Piston Needle (CPR-2005-01).

8.

Insert Catalyst Piston Needle (CPR-2005-01) into the Catalyst Needle Housing
(CPR-2003-02).















NOTE: Use caution not to bend the catalyst needle while performing the
remaining assembly procedures.

53900-1 NEEDLE GUIDE

53800-1 JAM NUT

CPR-2005-01 CATALYST NEEDLE

O-S-006 O-RING

CPR-2003-02 NEEDLE HOUSING

CPR-2012-02 CATALYST NEEDLE SEAT

O-S-012 O-RING