MaxPower Corp OceanAire Portable User Manual

Page 11

Advertising
background image

1)

Unplug unit. Open lower front door to
expose condensate bucket.

Remove bucket

.

airbossmanualpg9a

The Quick Connect Condensate Pump may be easily installed for one job, and just as
easily reinstall the bucket for the next job. Our quick connect kit consists of our specially
prepared and wired condensate pump, 20 feet of 3/8 plastic tubing, 2-10 inch pieces of
3/8 drain hose, 1 hose clamp, and 2 attaching screws.

Mounting
brackets,
One on each
side

Cushion
mounting
pad

TOOLS REQUIRED:
Phillips screwdriver
( pump brackets)

2) Start the first pump bracket mounting
screw into the second hole located on
the back side of the bucket tray. Just turn
the screw enough to catch a few threads.
Later you will slide the bracket under it.

First hole

Second hole

3) Remove electrical tape covering pre-wired line voltage
molex plug. This plug is located on the wiring harness
behind the condensate pump.

4) Push large line voltage molex
plug from the pump, into the
pre-wired receptacle. No need
to re-tape.

5) Disconnect molex plug
from the low voltage
micro switch that was
used by the bucket.

Installation
complete

Line
voltage
molex
plug
(for pump

Low voltage
molex plug
(for safety
switch)

7) Insert bracket mounting screw into
the pre-drilled hole that lines up with
the front pump mounting bracket.
Tighten this screw, then tighten the
rear mounting screw.

6) Push the low voltage molex
connector from the pump into the
pre-wired molex receptacle.

8) Remove the plastic plug from the
condensate line access hole. Push the
3/8 I.D. tubing through the hole and
attach to the pump discharge and secure
with the included clamp.

The production start date for Plug-in condensate pumps;
October 1, 2003 Serial Numbers dated
G4 and later.

Part Number Voltage
PC-1P 115v
PC-2P 208/230v

9

Advertising