MaxPower Corp OceanAire Portable User Manual

Page 7

Advertising
background image

ELECTRONIC THERMOSTAT
The electronic thermostat displays room temperature if the cooling system is on. Select the temperature
you want by pressing the ▲ or ▼ buttons. (The word COOL and the temperature setting is displayed for
5 seconds). The FAN button controls the evaporator fan motor . In the ON selection mode the fan runs
continuously. In the AUTO selection mode the fan cycles with the compressor. The OUTDOOR button is
not used in portable air conditioning. The MODE button controls the cooling function by selecting COOL
or OFF. The DAY/NIGHT allows day and night set points. A built in 4 minute time delay protects the
compressor from short cycling. Pressing the ▲ and ▼ simultaneously switches the display between
Celsius and Fahrenheit.
A two position rocker switch located next to the thermostat provides high fan when depressed upward,
low fan speed when depressed downward. The red light above or next to the rocker switch indicates tank
is full and needs to be emptied. (Except 5-ton which is factory equipped with a condensate pump).
FILTER
All units are
equipped with
1/2 or 1/8 inch
thick, washable,
mesh air filters
located behind
the evaporator
and condenser
inlet air grilles.
They can be
easily removed
and cleaned. Just
pull the grilles
out and remove
the filters.
SERVICE
CORD

All AirBoss
Series units are
equipped with
the standard ten
foot long service
cord with plug
configurations
and receptacle
requirements as
shown in this
chart. As of Au-
gust 1, 2004 units
will be equipped
with electric pro-
tection devices
(LCDI/AFCI), as
required by UL.

LCDI

(

Leakage Current

Detection & Interruption.
AFCI (Arc Fault Circuit
Interrupter).

5

airbossmanpg5

UNIT/MODEL

PLUG CONFIGURATION

RECEPTACLE

115 VOLT

PWC1011, PWC1211, PWC1811

PAC1011

, PAC1211, OWC1211,

OWC1811, OAC1211, OACH1211


NEMA-5-15R

115 VOLT

PAC18

, OAC18, OACH18


NEMA 5-20R

208/230 VOLT SINGLE PHASE

PAC1012,1212,1812,2412

OAC1212,1812,2412

OACH1212,1812,2412

PWC1012,1212,1812,2412,3612

OWC1212,1812,2412,3612


NEMA 6-20R

208/230 VOLT SINGLE PHASE

PAC3612

, OAC3612, OACH3612


PWC6012

, OWC6012


NEMA 6-30R

208/230 VOLT SINGLE PHASE

PAC6012,

OAC6012,

OACH6012


NEMA 6-50R

208/230 3 PHASE

OAC/

PAC3632

OACH3632

OWC3632,

PWC3632


NEMA L15-20R

208/230 3 PHASE

PAC6032

OAC6032,OACH6032

PWC6032

,OWC6032


NEMA L15-30R

460/480 3 PHASE

OAC/

PAC3634

OACH3634

PWC

/OWC

3634



NEMA L16-20R

460/480 3 PHASE

OAC6034,

PAC6034

OACH6034

PWC

/OWC

6034

NEMA L16-30R

15A-125 VOLT
NEMA 5-15P

20A-125 VOLT
NEMA 5-20P

20A-250 VOLT
NEMA 6-20P

30A-250 VOLT
NEMA 6-30P

50A-250 VOLT
NEMA 6-50P

20A-250 VOLT
NEMA L15-20P

30A-250 VOLT
NEMA L15-30P

30A-460 VOLT
NEMA L-16-30P

20A-460 VOLT
NEMA L16-20P