2. FILTERS

A clogged filter will cause the unit to operate at greatly reduced efficiencies. We recommend that the
filter be inspected on a regular bases every six weeks or more often depending on the environment. The
Evaporator washable filter is located behind the return air grille and can be easily removed by pulling the
grille out. The condenser washable filter is located in the lower backside of the unit. Remove by
loosening one screw holding retaining clip and pull out. The filters must be washed periodically as needed
by placing them in a dishwasher or soaking them in a solution of warm water and detergent for 10
minutes. Then rinsing them clean with hot water and shaking excess moisture from filter.



3. CONDENSATE PUMP

When servicing pump follow these steps;

1. Make certain that the unit is disconnected from the power source before attempting to service or
remove any component.

2. Be sure the floats move freely. Clean as necessary.

3. Remove the volute and check for obstructions. Clean as needed.

4. Clean the tank with warm water and mild soap when mineral deposits are visible.

5. Check the inlet and outlet piping. Clean as necessary. Be sure there are no kinks in the lines that would
inhibit flow.

GENERAL

When necessary maintenance steps outlined above are followed, the air conditioner will provide long and
reliable service. The refrigeration and electrical circuits of the system should only be serviced by a fully
qualified service technician.