2. (CAUSE) Thermostat

(REMEDY) Examine the control unit for loose wires. Tighten any loose connections. Wait 4-minutes
before re-start.

3. (REASON) High Pressure Switch tripping turning unit off.

(FIXING) Depress high pressure switch red button, check for loose wire connections, broken or burned
contacts. If switch is defective, replace.

4. (CAUSE) Compressor contactor open or burned. (CURE) Replace

5. (REASON) Refrigerant leak-no freon. (REMEDY) Locate leak and repair. Evacuate unit and recharge.

6. (CAUSE) Loose or defective wires. (FIXING) Tug on wires to see if they will separate from
connections.

7. (REASON) Defective compressor (REMEDY) Check for shorts, opens and grounds. Remove and
replace compressor.

8. CAUSE) Shorted or open run capacitor (FIXING) Remove and replace.

9. (CAUSE) Defective tank full unit cut-out switch. (REMEDY) Check and replace.

10 (CAUSE) Condensate tank could be full, but, red light might be defective. (REMEDY) Check tank and
replace red light if defective.

PROBLEM: COMPRESSOR STARTS AND RUNS, BUT, EVAPORATOR FAN DOES NOT RUN.

1. (CAUSE) Faulty rocker switch (REMEDY) Replace

2. (REASON) Open fan motor coil circuit (FIXING) Replace fan motor.

3. (CAUSE) Shorted or open fan motor capacitor (REMEDY) Replace capacitor.

4. (REASON) Loose or defective wires (REMEDY) Trace and repair