NOTE


If the vehicle’s engine stalls, restrict pressure in the fuel
line by turning the gate valve on the T-adaptor (#060-
4500)

clockwise 1/4 turn. Re-start the car and repeat

Step 12. If the vehicle’s engine stalls again, repeat this
procedure until Step 12 is completed.


13.

Turn off the vehicle's engine.


14.

Verify the

Pressure Adjust

regulator on the unit is completely open.

15.

Press and hold the

Fill/Purge

button for five seconds. This will relieve pressure in the

output (

red

) hose. Release the

Fill/Purge

button.

/!\ WARNING


Flammable Liquid can squirt out of pressurized lines when connecting or disconnecting.
Wear Safety goggles.
Obtain ZERO pressure before connecting or disconnecting any fuel lines or adaptors.
Wear chemical resistant gloves when connecting or disconnecting fittings and adaptors.
Wrap shop towel around pressure fittings and adaptors when disconnecting.
Avoid exposure to flames, sparks, hot engine parts, and other ignition sources.
Explosion or flame or exposure to flammable liquid and vapors can cause injury.

16.

Close the gate valve on the T-adaptor (#060-4500), and then carefully remove the output (

red

) hose from

the T-adaptor (#060-4500).