Continuous Injection System (CIS) Cleaning Procedure

Follow the steps below to circulate the cleaning mixture through the CIS fuel distributor to

clean the

pressure regulator and the top portion of the fuel distributor.

1.

Verify

that

CIS Setup Steps 1-18

above have been completed before continuing.

At this point, refer to appropriate Intake System Cleaning Procedure section for proper intake

cleaning, and Vacuum gauge connections in the vehicle diagnostics chapter.

2.

Refer to the vehicle's service manual for the manufacturer's recommended PSI.

3.

Press and hold the

Start

button.


4.

Close

the

Pressure Adjust

regulator clockwise until the

Fuel Pressure

gauge on the

unit displays the vehicles operating pressure and the

Up Arrow

LED stays illuminated

without flashing. This will clean the CIS system and filter the contaminants through
the unit’s filtering system.

5.

Release

the

Start

button and continue to turn the

Pressure Adjust

regulator

clockwise until it is completely closed.

• Make a note of the fuel pressure reading; this is the true opening pressure of the vehicle's pressure

regulator without vacuum assist when the engine is at normal operating temperature.

CAUTION:

Do not open or move sensor plate / air door on the
engine when the fuel distributor is pressurized. The CIS
system will spray fuel into the engine while it is not
running.

6.

Press

the

­

button to increases the time, or the button to decreases the time until

the

Time

LED displays 10 minutes.

7.

After the 10 minutes has expired on the

Time

LED display, press the

Start

button

until the pressure rises to the previous system pressure, and release.

Advertising