10.

When the run time expires, the cleaning is complete. The unit will automatically shut

off and purge the pressure lines for five seconds. The

Cycle Complete

LED on the

control panel will illuminate, and the unit’s alarm will sound.


11.

Turn OFF the vehicle's ignition.


12.

Turn the

Pressure Adjust

regulator counterclockwise on the unit to open it. Press and

hold the

Fill/Purge

button for four seconds to relieve pressure from the output (

red

)

hose. Release the

Fill/Purge

button.

13.

Loosen the vehicle's gas cap to relieve fuel tank pressure, and then re-install cap.



IMPORTANT

Wrap a shop towel around pressure fittings before
disconnection to protect against residual fuel spray.


14.

Disconnect the battery leads, hoses, and adaptors. Return the vehicle's fuel

system to its normal operating condition by re-connecting the vehicle's fuel lines.


15.

Start the vehicle

and verify that there are no leaks.

16.

Test drive the vehicle for three miles immediately following the cleaning service to

flush all detergent from the vehicle's fuel and exhaust systems.