1 to install a model 7xf rigid single rod probe, 2 to install a model 7x1 flexible single rod probe – Orion Instruments Eclipse 705 User Manual

Page 13

Advertising
background image

13

57-600 Eclipse

®

Guided Wave Radar Transmitter

2. Ratio of Diameter: Length (A:B) is 1:1 or greater; any

ratio <1:1 (e.g., a 2"

× 6" nozzle = 1:3) may require a

Blocking Distance and/or DIELECTRIC adjustment
(see Section 2.6.5.2 Measurement Type: Level and
Volume).

3. No pipe reducers (restrictions) are used.

• Probe is kept away from conductive objects to ensure proper

performance. See Probe Clearance Table below. A lower gain
(increase in DIELECTRIC setting) may be necessary to
ignore certain objects (see Section 2.6.5.4 Measurement
Type: Interface and Volume).

2.4.3.1 To install a Model 7xF rigid single rod probe:

ΠMake sure the process connection is at least 2" NPT or a

flanged mounting.

 Carefully place the probe into the vessel. Align the gasket

on flanged installations.

Ž Align the probe process connection with the threaded or

flanged mounting on the vessel.

 For threaded connections, tighten the hex nut of the probe

process connection. For flanged connections, tighten flange
bolts.

 Probe can be stabilized by placing into a non-metallic cup

or bracket at the bottom of the probe. A TFE bottom
spacer (P/N 89-9114-001) is optional for mounting into
a metallic cup or bracket.

NOTE: If the transmitter is to be installed at a later time, do not remove

the protective cap from the probe. Do not use sealing com-
pound or TFE tape on probe connection to transmitter as this
connection is sealed by a Viton

®

O-ring.

2.4.3.2 To install a Model 7x1 flexible single rod probe:

ΠMake sure the process connection is at least 2" NPT or a

flanged mounting.

 Carefully place the probe into the vessel. Align the gasket

on flanged installations.

Distance

to Probe

Acceptable Objects

<6"

Continuous, smooth, parallel conductive
surface, for example a metal tank wall;
important that probe does not touch wall

>6"

<1" (25mm) diameter pipe and beams,
ladder rungs

>12"

<3" (75mm) diameter pipe and beams,
concrete walls

>18"

All remaining objects

PROBE CLEARANCE TABLE

A

B

Advertising