8

57-600 Eclipse

®

Guided Wave Radar Transmitter

2.0

Complete Installation

This section provides detailed procedures for properly
installing and configuring the ECLIPSE Guided Wave
Radar Level Transmitter.

2.1

Unpacking

Unpack the instrument carefully. Make sure all components
have been removed from the packing material. Check all the
contents against the packing slip and report any discrepan-
cies to the factory.

Before proceeding with the installation, do the following:

• Inspect all components for damage. Report any damage to

the carrier within 24 hours.

• Make sure the nameplate model number on the probe and

transmitter agree with the packing slip and purchase order.

• Record the model and serial numbers for future reference

when ordering parts.

Model Number

Serial Number

2.2

Electrostatic Discharge (ESD)
Handling Procedure

Magnetrol

®

electronic instruments are manufactured to the

highest quality standards. These instruments use electronic
components that may be damaged by static electricity pre-
sent in most work environments.

The following steps are recommended to reduce the risk of
component failure due to electrostatic discharge.

• Ship and store circuit boards in anti-static bags. If an anti-

static bag is not available, wrap the board in aluminum foil.
Do not place boards on foam packing materials.

• Use a grounding wrist strap when installing and removing

circuit boards. A grounded workstation is recommended.

• Handle circuit boards only by the edges. Do not touch

components or connector pins.

• Make sure that all electrical connections are completely

made and none are partial or floating. Ground all equip-
ment to a good, earth ground.