D. programming the controller, D.1. blast chilling modes d.2. pc connection mode, Programming 17 – American Panel Blast Chiller BCIP User Manual

Page 19

Advertising
background image

PROGRAMMING

17


D. Programming The Controller

WARNINGS!


Read and carefully follow all of the instructions in this manual before attempting to install this equipment.
Installation must be performed by a qualified Service Agency approved and authorized by American Panel
Corporation. Doing otherwise may void the warranty.
Any changes made to the equipment without authorization from the factory will void the warranty.

PREPARATION

9 Check the integrity of the unit once it is unpacked.
9 Check to make sure the floor is level.
9 Check that the available power supply (Voltage, # of phases, Hz, Amps, max. fuse size) corresponds to the ratings on

the nameplate and that correctly rated electrical protection is provided (VOLTAGE MUST BE WITHIN

± 5% FROM

THE NAMEPLATE VALUE).

9 Make certain that adequate drainage is provided.

D.1. Blast Chilling Modes

AP40BC250-12,

AP40BC250-2-12, BCCP-1, BCCP-2, and BCIP are equipped with a high versatility electronic

controller allowing the chef to choose between automatic and manual operation.

Automatic Mode

In the first part of the cycle the air temperature is lowered to a preset temperature (10

0

F). When the food core

temperature reaches a preset breaking temperature point (60

0

F) the unit will switch to the second part of the cycle which

is design to protect the food from getting frozen. The air temperature will rise to a preset temperature range (28

0

F to

35

0

F). The chilling cycle is complete when the food core temperature reaches the desired end temperature (40

0

F).

Manual Mode

In the manual mode the blast chilling operation will last for a preset time. In the first part of the manual cycle the

air temperature is lowered and held to a preset temperature (10

0

F). Once the time for the first part of the cycle expires the

unit will switch to the second part of the cycle. The air temperature is held at a preset temperature range (28

0

F to 35

0

F) for

the remaining time (1 hour).

Note: At the end of any blast chilling cycle the unit will automatically switch to a holding mode which will keep the food at
38

0

F until START/STOP button is pressed to end the cycle.


D.2. PC Connection Mode

The unit can be programmed and operated from a remote PC via modem and software (Windows 95, 98, 2000,

NT, and XP). Maximum distance is 4000 feet. Full instructions are supplied on a computer disc, which is furnished when
the computer connection is ordered. All connections should be made exactly as shown in the connection diagram, drawing
number 98002-01B on page 38 of this manual.

The application allows the operator to save the programmed parameters and the events memory to PC for

archival purposes. The software’s interface emulates the control panel.