PROGRAMMING

20

Use

and

buttons to scroll to the baud rate of your computer. Most computers

use 38400 baud rate.

Press

when done.

If “PC CONNECTION” is set to “NO”, the controller will jump to the “PRINTER
CONNECTION” screen. If “PC CONNECTION” is set to “YES”, the controller will ask
you to select the unit’s ID number.

To change the ID number for a particular chiller, use

and

buttons. Press

when done.

Note: If more than one chiller is connected to the PC, each chiller must have a different ID number. Thirty-two ID numbers
are available.

Use

and

buttons to chose Yes or No. Select “YES”, only if the unit is

equipped with a printer, otherwise select “NO”. Press

when done.

Use

and

buttons to scroll to the printer’s baud rate. The provided printer uses

1200 baud rate.

Press

when done.

Use

and

buttons to change the number of food probes. Press

when

done.

Note: The number of food probes you set should be equal with the number of food probes available on the unit.

Use

and

buttons to chose Yes or No. Select “YES”, if the unit is equipped

with UV light, otherwise select “NO”. Press

when done.

Use

and

buttons to choose Yes or No. Defrost Cycle is standard for all A.P.C

blast chillers. Set the value to “YES”. Press

when done.

Use

and

buttons to change the number of available air probes. Press

when done.

Note: The number of air probes you set should be equal with the number of air probes
available on the unit.

AP40BC250-12 and BCCP-1 units are standard equipped with one air probe; AP40BC250-2-12, BCCP-2, and BCIP units
are equipped with two air probes, one for each compartment.

NAFEM communication is an optional feature. Select “Yes” only if NAFEM
communication kit has been purchased.