Operational, basic, and advanced parameters, Network settings, Appendix a – Aastra Telecom SIP 480I User Manual

Page 295

Advertising
background image

Operational, Basic, and Advanced Parameters

41-001129-00 Rev 09, Release 1.4.1

A-5

Configuration Parameters

Appendix A

Operational, Basic, and Advanced Parameters

The following sections provide the configuration parameters you can configure on
the IP phone. Each parameter table includes the name of the parameter, a
description, the format, default value, range, and example. The table also provides
the method for which the parameters can be configured (IP phone UI, Aastra Web
UI, or configuration files).

Network Settings

Parameter
dhcp

DHCP
(in Web UI)

IP phone UI

Options->Network Settings

Aastra Web UI

Advanced Settings->Network

Configuration Files

aastra.cfg, <mac>.cfg

Description

Enabling DHCP will populate most of the network information. The DHCP
server should serve the network information that the IP phone requires. If
the IP phone is unable to get any required information then it should be
entered manually. Parameters affected: ip. Use "0" to disable DHCP and
"1" to enable DHCP.

Format

Integer

Default Value

1

Range

0 or 1

Example

dhcp: 1

Parameter
ip

Ip Address
(in Web UI)

IP phone UI

Options->Network Settings

Aastra Web UI

Advanced Settings->Network

Configuration Files

aastra.cfg, <mac>.cfg

Description

This parameter assigns a static IP address to the IP phone device.

Format

IP address

Default Value

0.0.0.0

Range

Not Applicable

Example

ip: 192.168.0.25