3-1

Chapter 3: Troubleshooting

Chapter 3

Troubleshooting

3-1

Troubleshooting Procedures

Use the following procedures to troubleshoot your system. If you have

followed all of the procedures below and still need assistance, refer to the

‘Technical Support Procedures’ and/or ‘Returning Merchandise for Service’

section(s) in this chapter.

Note: Always disconnect the power cord before adding, changing

or installing any hardware components.

Before Power On

1. Make sure no short circuits exist between the motherboard and chassis.

2. Disconnect all ribbon/wire cables from the motherboard, including those

for the keyboard and mouse.

3. Remove all add-on cards.

4. Install one CPU (making sure it is fully seated) and connect the chassis

speaker and the power LED to the motherboard. (Check all jumper

settings as well.)

5. Use only the correct type of onboard CMOS battery as recommended by

the Manufacturer. Do not install the onboard battery upside down to

avoid possible explosion.

No Power

1. Make sure no short circuits exist between the motherboard and the chas-

sis.

2. Verify that all jumpers are set to their default positions.

3. Check that the 115V/230V switch on the power supply is properly set.

4. Turn the power switch on and off to test the system.

5. The battery on your motherboard may be old. Check to verify that it still

supplies ~3VDC. If it does not, replace it with a new one.

No Video

1. If the power is on but you have no video, remove all the add-on cards

and cables.

2. Use the speaker to determine if any beep codes exist. Refer to the

Appendix for details on beep codes.