Plan out location of all components supplied in your kit as follows:

Suggested Locations for Equipment Mounting

(a)

The 8 Zone Master Panel Box should always be located out of sight (i.e.
cupboard, wardrobe or in an area it would not be easily seen).


(b)

The 8 Zone PINKERTON Keypad should be situated near the main entry/exit
point (usually inside the main front door).


(c)

The External Siren (enclosed in siren cover along with Tamper Button)
should be mounted in a prominent position in full view. This would normally
be mounted under the eaves at the front of the house in a corner position. The
strobe light is mounted onto the siren cover.


(d)

The Flush Mount Reed Switches are most suitable to be mounted on the front
and back doors.


(e)

The Passive Infra Red Detectors (PIR’S) should be situated to cover high
access areas (eg: Hallways and areas of high importance or value).


(f)

The Emergency Button should be located in a position for quick easy access
in an emergency or panic situation (suitable position could be a bedside
location).


(g)

The Pinkerton Security Alarm Warning Stickers should be placed on the front
face of the Siren cover and on an outside window in clear view.


Note:

PIR’s are susceptible to environmental conditions such as wind and air
movement. Windows must be closed when system is armed to avoid possible
false alarms.

Step 2:

(a)

Install all cabling to component positions.


(b) Austel

approved

cables must be installed if the system is to be monitored.

Use

two pair (4 core) 14/0.20 and Figure 8 (2 core) 14/0.20.

REMEMBER TO MARK YOUR CABLES.