18
Evolver NE Solventborne Robotic Atomizers - Operation
NOTES
Fluid Flow Rate
Fluid flow is adjusted through the robot PLC by vary-
ing the pilot pressure to the on-board fluid regulator
within the spray applicator. Fluid pressures from the
circulating system may exceed the maximum fluid
pressure rating of the Evolver applicator. Because
of these high fluid pressures, a manual step-down
fluid regulator must be used.
Trigger Control Air
The Evolver applicators require a minimum of 70 psig
trigger control air pressure to ensure proper operation
of the applicator piston.
Target Distance
The distance between the applicator tip and the article
being painted should be between 10-14 inches. Exces-
sive distance causes a waste of coating material.
AA-05-01.5