18

Evolver NE Solventborne Robotic Atomizers - Operation

NOTES

Fluid Flow Rate

Fluid flow is adjusted through the robot PLC by vary-

ing the pilot pressure to the on-board fluid regulator

within the spray applicator. Fluid pressures from the

circulating system may exceed the maximum fluid

pressure rating of the Evolver applicator. Because

of these high fluid pressures, a manual step-down

fluid regulator must be used.

Trigger Control Air

The Evolver applicators require a minimum of 70 psig

trigger control air pressure to ensure proper operation

of the applicator piston.

Target Distance

The distance between the applicator tip and the article

being painted should be between 10-14 inches. Exces-

sive distance causes a waste of coating material.

AA-05-01.5