26

Evolver NE Solventborne Robotic Atomizers - Maintenance

SERVICE

Because we want to provide our users with the most

up-to-date technology possible, we are constantly

seeking to improve products. If a change in product

configuration occurs after it is on the market, we will

implement that technology in future production and,

if practical, make it available to current users. The

following service information is based on standard

specifications and procedures for this product. If you

find some minor deviations between this information

and your equipment because of design or manufac-

turing changes, contact your Ransburg representative

to resolve the difference.

>

Unexpected robot movement can be hazard-

ous. Do not adjust or repair the spray applicator

when the robot is operating or waiting to start.

The robot must be locked out and tagged out per

OSHA. prior to removing the applicator from the

robot manifold assembly.

W A R N I N G

!

SPRAY HEAD ASSEMBLY

Before performing any work on the spray applicator,

always flush the fluid passages and blow dry with

push-out air, and wipe the spray applicator clean.

Refer to "Gun Cleaning/Service" in the "Maintenance"

section, for instructions on how to properly clean

the spray applicator. Depressurize all fluid and air

pressures before removing the applicator from its

manifold. Always work in a clear, clean space to

minimize parts loss and damage.

Rear Needle Replacement

(See Figure 5)

1. Remove the air cap, fluid tip, and the fluid

nozzle as described in Steps 1 through 13 of the

"Gun Cleaning/Service"" in the "Maintenance" sec-

tion.

2. Remove the rear needle [6] and lock nuts [4]

and [5] as an assembly. Pull the assembly out

from the rear of the spray head.

>

As the spray head is removed from the valve

manifold assembly, a certain amount of residual

fluid may be present. Care must be taken not

to allow this fluid to drain into the high voltage

terminal rings or air passages.

C A U T I O N

!

>

Eye protection should be worn while servic-

ing gun.

W A R N I N G

!

>

Disassemble spray head only enough

to remove and replace defective parts.

For instance, if only replacing the front

electrode it is not necessary to remove the

fluid nozzle.

NOTE

>

To prevent damage, always lubricate the

o-rings located on the underside of the

spray head.

NOTE

>

Fluid seal [29], seal washer [28], and seal spring

[27], will come free at this point. Place hand over

end as not to drop parts.

C A U T I O N

!

AA-05-01.5