Evolver NE Solventborne Robotic Atomizers - Maintenance

7. When placing the diaphragm [10], remove the

screw [14] that holds both halves together. Inspect

o-ring [9] for damage. To reassemble, make sure that

the side is toward the lower support [8]. Reinstall

screw and tighten. Be careful not to over tighten. If

the diaphragm is inserted wrong, damage will occur.

Push the

diaphragm assembly down in valve

body aligning the screw holes.

8. Tighten regulator bonnet [12] into the block as-

sembly [3] securely with the six (6) screws [15] in

an alternating 180

° method, torque to 8-10 lbs•in

(0.9-1.1 Nm).

9. Reinstall the regulator cap [13] and o-ring [6].

Torque to 125-135 lbs•in (14.1-15.3 Nm).

NOTES

>

When replacing the needle seat, be

cautious so that the plastic threads are not

stripped by cross threading.

NOTE

AA-05-01.5