Ransburg Evolver NE A11279-XX, A11281-XX, A11775-XX, A11776-XX User Manual

Page 33

Advertising
background image

28

Evolver NE Solventborne Robotic Atomizers - Maintenance

8. Reassemble the remaining parts as shown in

Figure 6 making sure that the alignment tab on the

bushing [14] lines up with the align groove in the

body [19].

9. Torque the seal carriage [13] to 35-40 lbs•in (4.0-

4.5 Nm).

10. If the u-cup needs to be replaced, assemble

on piston plate [9] and push both onto shaft, tighten

securely with piston nut [7] and install in body as

one assembly.

11. Assemble the remainder of the applicator head

as stated earlier.

12. If the locking tab plug connection [24] needs

to be replaced, remove socket head screw [22] and

connection plug [24] from body.

13.

Reinstall the connection plug [24] into the

body, making sure the tabs on the bottom align

with the notches in the body [19].

14. Insert and tighten the screw [22], making sure

the tabs remain inside the notches [24] in the

body.

NOTES

AA-05-01.5

Advertising