Evolver NE Solventborne Robotic Atomizers - Maintenance

PROCEDURES

Applicator Cleaning/Service

(See Figure 5)

1. Flush the paint supply line and the applicator paint

passages using a solvent which is compatible with

the material being sprayed. Continue to flush until

all traces of paint are gone.

2. Turn off the solvent supply, actuate paint push-

out air at color changer and trigger the applicator.

Allow all of the fluid to drain from the spray applica-

tor fluid passages.

3. Clean the exterior surfaces of the spray applicator

with a solvent soaked rag.

4. Remove end cap [1]. Removing the end cap

releases tension on all internal spray head compo-

nents. Remove needle spring [2] and valve spring [3],

which are loose after removing the piston cap.

>

Never attempt to clean the air cap holes

with a wire or other metal object. Doing so

may damage the air cap, resulting in distortion

of the spray pattern.

!

C A U T I O N

5. Remove the air cap retainer [36] and air cap

[35]. Soak in a solvent if necessary. If paint remains

in the air cap holes, clean with a toothpick or similar

soft wood object. Air caps are best cleaned in an

ultrasonic cleaner.

6. Remove the air cap locator [33] and fluid tip

[34]. Clean using a solvent.

7. Tightly grip the plastic needle [6] and unscrew

counter-clockwise to remove the front needle tip.

A short piece of H-2339 tubing (1/4" OD x 0.175" ID)

pressed over the front needle will assist in unscrew-

ing the assembly. If required, use needle nose pliers

with masking tape or duct tape. Carefully clean with

a solvent. Replace any parts that show signs of wear

or damage.

>

If using needle nose pliers to unscrew the

front needle, be very careful. Do not grip on the

tapered sealing surface. If the pliers slip, they

could damage the tapered sealing surface of

the needle.

C A U T I O N

!

8. Remove fluid nozzle [32] by unscrewing counter-

clockwise. Inspect o-ring [30] and all passages for

build-up or damage. Clean or replace as necessary.

Lubricate and reinsert o-ring into applicator barrel

and reinstall fluid nozzle. Torque fluid nozzle to 25

lbs•in (2.82 Nm).

>

There should be a small gap between the

fluid nozzle and the applicator barrel after

tightening.

NOTE

9. After cleaning, insert the front needle tip [31] back

into the spray head assembly. Apply Loctite #222, low

strength (purple) thread-locker, to the threads of the

tip assembly before reassembly.

>

DO NOT use the A11218-00 tip assembly [31]

with electrostatic voltage. The electrode tip is for

non-electrostatic applications ONLY.

W A R N I N G

!